$160.0052 - Power & Control Area Fundamentals
Course Name: TEG_103_UP_CA_FUND_OL_Class_52_Online
This class provides a broad overview of Bulk Power entities including Balancing Authorities, Generation, Transmission, Interconnection, Modeling and Personnel Standards.
Credit: 8CEH (8EO,8OP,8STDS,8PROF)
$20.0052.1 - Real Power Balancing Control Performance
TEG_103_CA_FUND_OL_CLASS_52_SECTION_1
NERC Standard BAL-001
Calculation of ACE formulas, Overlap Regulation Service, Measurements, CPS1, CPS2 and compliance.
(Credit: 1CEH, 1STDS, 1OP, 1PROF)
$20.0052.2 - Facility Connection Requirements
TEG_103_CA_FUND_OL_CLASS_52_SECTION_2
NERC Standard FAC-001
Requirements, measures, compliance and evels of non-compliance.
(Credit: 1CEH, 1STDS, 1OP, 1PROF)
$30.0052.3 - Dynamics Data Requirements and Reporting Procedures, Development of Interconnection-Specific Steady State System Models
TEG_103_CA_FUND_OL_CLASS_52_SECTION_3
NERC Standard MOD-013
NERC Standard MOD-014
Basic Electricity terms, definitions, and properties.
(Credit: 1.5CEH, 1.5STDS, 1.5OP, 1.5PROF)
$15.0052.4 - Coordination Plans for New Facilities
TEG_103_CA_FUND_OL_CLASS_52_SECTION_4
NERC Standard FAC-002
Coordination of Plans for New Facilities: All fuel types, characteristics and methods of power generation, transmission and distribution Monitoring System Conditions as well as responsibilities for monitoring and information flow, those to/from information is required, forecasting and deviation monitoring.
(Credit: .75CEH, .75STDS, .75OP, .75PROF)
$30.0052.5 - Interchange Transaction Tagging, Implementation and Modifications
TEG_103_CA_FUND_OL_CLASS_52_SECTION_5
NERC Standard INT-001
NERC Standard INT-003
NERC Standard INT-004
Types and methods of transmission and delivery, voltage levels, tagging and reservation.
(Credit: 1.5CEH, 1.5STDS, 1.5OP, 1.5PROF)
$30.0052.6 - Control Center Operating Personnel Responsibility and Authority
TEG_103_CA_FUND_OL_CLASS_52_SECTION_6
NERC Standard PER-001
Generation, transmission, load balancing, power dispatchers/coordinators, and control areas Response to Transmission Limit Violation as well as required responses to SOL and IROL violations.
(Credit: 1.5CEH, 1.5STDS, 1.5OP, 1.5PROF)
$15.0052.7 - Reliability Responsibilities and Authority
TEG_103_CA_FUND_OL_CLASS_52_SECTION_7
NERC Standard TOP-001
Regulatory and operation entities, FERC, NERC, ISO, etc. Automatic Generation Control. Responsibility and time frame for reporting any inability to meet ACE time limits or minimum availability requirements, BA AGC and ACE calculation relating to Regulating Reserves, and compliance requirements.
(Credit: .75CEH, .75STDS, .75OP, .75PROF)
The Energy Group