welcome guest [ login | register ]
ERROR: Code 1

$160.0056 - Advanced Voltage Collapse and Contingencies

Course Name: TEG_103_ADV_VOLTCOL_CONT_OL_Class_56_Online

This class is an advanced version of Class 55 related to Voltage, SOL/IROL, AGC and Communications.

Credit: 8CEH (8STDS,8PROF,4EO)

$20.0056.1 - Voltage and Reactive Control

TEG_103_ADV_VOLTCOL_CONT_OL_CLASS_56_SECTION_1

NERC Standard VAR-001
NERC Standard EOP-003
Voltage levels, reactive flows, monitoring, controls, emergencies and maintenance of limits in addition to emergency measures involving Load Shedding to prevent uncontrolled failure of components of cascading outages of the Interconnection.

(Credit: 1CEH, .5EO, 1STDS, 1OP, 1PROF)

View Syllabus

$20.0056.2 - Transmission Operations

TEG_103_ADV_VOLTCOL_CONT_OL_CLASS_56_SECTION_2

NERC Standard TOP-004-2
NERC Standard EOP-001-1
Instability, uncontrolled separation, emergencies, cascading outages and contingencies. It will also cover emergency planning requirements to be coordinated by Transmission Operators, Balancing Authorities and Reliability Coordinators.

(Credit: 1CEH, .5EO, 1STDS, 1OP, 1PROF)

View Syllabus

$20.0056.3 - Operations Reliability Information

TEG_103_ADV_VOLTCOL_CONT_OL_CLASS_56_SECTION_3

NERC Standard TOP-005
NERC Standard EOP-006
Types of information required to be communicated, methods of communication and record retention in emergency and non-emergency circumstances. It will also cover the responsibilities related to disturbance reporting.

(Credit: 1CEH, .5EO, 1STDS, 1OP, 1PROF)

View Syllabus

$20.0056.4 - Monitoring System Conditions

TEG_103_ADV_VOLTCOL_CONT_OL_CLASS_56_SECTION_4

NERC Standard TOP-006
NERC Standard EOP-007
Responsibilities for monitoring and information flow, emergencies, those to/from information is required, forecasting and deviation monitoring. It will also cover capacity and energy emergency situations, requirements and measures.

(Credit: 1CEH, .5EO, 1STDS, 1OP, 1PROF)

View Syllabus

$20.0056.5 - Reporting SOL and IROL Violations

TEG_103_ADV_VOLTCOL_CONT_OL_CLASS_56_SECTION_5

NERC Standard TOP-007-0
NERC Standard EOP-005-1
Requirements, emergencies, measures and compliance related to Standard Operating Limits (SOL) and Interconnection Reliability Operating Limits(IROL) in addition to covering System Restoration Plans.

(Credit: 1CEH, .5EO, 1STDS, 1OP, 1PROF)

View Syllabus

$20.0056.6 - Response to Transmission Limit Violation

TEG_103_ADV_VOLTCOL_CONT_OL_CLASS_56_SECTION_6

NERC Standard TOP-008-1
NERC Standard EOP-004-1
Required emergency and non-emergency responses to SOL and IROL violations. Reliability Coordination for System Restoration and Plans for Loss of Control Center Functionality.

(Credit: 1CEH, .5EO, 1STDS, 1OP, 1PROF)

View Syllabus

$20.0056.7 - Automatic Generation Control

TEG_103_ADV_VOLTCOL_CONT_OL_CLASS_56_SECTION_7

NERC Standard BAL-005-0.1b
NERC Standard EOP-008-0
Responsibility and timeframe for reporting any inability to meet ACE time limits or minimum availability requirements, BA AGC and ACE calculation relating to Regulating Reserves, emergency and non-emergency compliance requirements. Documentation of Blackstart Generating Unit Test Results.

(Credit: 1CEH, .5EO, 1STDS, 1OP, 1PROF)

View Syllabus

$20.0056.8 - Communication and Coordination

TEG_103_ADV_VOLTCOL_CONT_OL_CLASS_56_SECTION_8

NERC Standard COM-002
NERC Standard EOP-002
Transmission Operators responsibility for communication with RC and the method of communication and assurance of accuracy of information communicated under normal and emergency circumstances. It also covers the responsibilities and requirements for Reliability Coordinators as relates to System restoration following an outage.

(Credit: 1CEH, .5EO, 1STDS, 1OP, 1PROF)

View Syllabus