Course Listing
$160.00 51 - Emergency Operations Procedures
TEG_103_EOP_OPC_OL_CLASS_51
Each Transmission Operator and Balancing Authority needs to develop, maintain, and implement a set of plans to mitigate operating emergencies. These plans need to be coordinated with other Transmission Operators and Balancing Authorities, and the Reliability Coordinator.
Credit: 8CEH (8OP,8STDS,8PROF,8EO)
Sections
- 51.1 - Emergency Operations Planning
- 51.2 - Capacity and Energy Emergencies
- 51.3 - Load Shedding Plans
- 51.4 - Disturbance Reporting
- 51.5 - System Restoration Plans
- 51.6 - Reliability Coordination
- 51.7 - Establish, Maintain and Document Regional Blackstart Capacity Plan
- 51.8 - Plans for Loss of Control Center
- 51.9 - Documentation of Blackstart Generating Unit Test Results
$160.00 52 - Power & Control Area Fundamentals
TEG_103_UP_CA_FUND_OL_Class_52_Online
This class provides a broad overview of Bulk Power entities including Balancing Authorities, Generation, Transmission, Interconnection, Modeling and Personnel Standards.
Credit: 8CEH (8EO,8OP,8STDS,8PROF)
Sections
- 52.1 - Real Power Balancing Control Performance
- 52.2 - Facility Connection Requirements
- 52.3 - Dynamics Data Requirements and Reporting Procedures, Development of Interconnection-Specific Steady State System Models
- 52.4 - Coordination Plans for New Facilities
- 52.5 - Interchange Transaction Tagging, Implementation and Modifications
- 52.6 - Control Center Operating Personnel Responsibility and Authority
- 52.7 - Reliability Responsibilities and Authority
$140.00 53 - Effective Communications
TEG_103_ECOMM_OPC_OL_Class_53_Online
This class covers various standards relating to communications including telecommunications, human, data, interchange, and looks at facility ratings and personnel training requirements.
Credit: 7CEH (7OP,7STDS,7PROF)
Sections
- 53.1 - Telecommunications
- 53.2 - Communications and Coordination
- 53.3 - Interchange Information
- 53.4 - Automatic Generaton Control
- 53.5 - Facility Ratings Methodology
- 53.6 - Operations Personnel Training
$160.00 54 - UFLS, Communication & System Protection
TEG_103_UFLS_COM_SP_OL_CLASS_54
The class is focused on Under Frequency Load Shedding standards but also includes Operator and Reliability Coordinator credentials, staffing, training and compliance.
Credit: 8CEH (8OP,8STDS,8PROF)
Sections
- 54.1 - Development and Documentation of Regional UFLS Programs
- 54.2- Assuring Consistency with Regional UFLS Programs
- 54.3 - Under Frequency Load Shedding Equipment Maintenance Programs
- 54.4 - UFLS Performance Following an Under Frequency Event
- 54.5 - Operating Personnel Credentials
- 54.6 - Reliability Coordination-Staffing
- 54.7 - Training and Standards Requirements (Part 1)
- 54.8 - Monitoring and Compliance (Part 2)
$160.00 55 - Basic Voltage, SOL/IROL, Power Flow
TEG_103_BS_VOLT_SOL_PF_OL_Class_55_Online
This class is devoted to standards related to Voltage, SOL/IROL, AGC, and Communications.
Credit: 8CEH (8OP,8STDS,8PROF)
Sections
- 55.1 - Voltage and Reactive Control
- 55.2 - Transmission Operation
- 55.3 - Operations Reliability Information
- 55.4 - Monitoring System Conditions
- 55.5 - Reporting SOL and IROL Violations
- 55.6 - Response to Transmission Limit Violation
- 55.7 - Automatic Generation Control
- 55.8 - Communication and Coordination
$160.00 56 - Advanced Voltage Collapse and Contingencies
TEG_103_ADV_VOLTCOL_CONT_OL_Class_56_Online
This class is an advanced version of Class 55 related to Voltage, SOL/IROL, AGC and Communications.
Credit: 8CEH (8STDS,8PROF,4EO)
Sections
- 56.1 - Voltage and Reactive Control
- 56.2 - Transmission Operations
- 56.3 - Operations Reliability Information
- 56.4 - Monitoring System Conditions
- 56.5 - Reporting SOL and IROL Violations
- 56.6 - Response to Transmission Limit Violation
- 56.7 - Automatic Generation Control
- 56.8 - Communication and Coordination
$160.00 57 - Balance & Disturbance Control
TEG_103_BAL_DIST_OL_Class_57_Online
This class relates to Disturbance Control and Reporting, Emergencies, Restoration Plans, and Load Shedding Plans.
Credit: 8CEH 8OP,8STDS,8PROF,4EO)
Sections
- 57.1 - Disturbance Control Performance
- 57.2 - Capacity and Energy Emergencies
- 57.3 - Frequency Response and Bias
- 57.4 - System Restoration Plans
- 57.5 - Automatic Generation Control
- 57.6 - Inadvertent Interchange
- 57.7 - Disturbance Reporting
- 57.8 - Load Shedding Plans
$160.00 58 - Restoration Interchange Coordination and Emergency Planning
TEG_103_INT_COORD_EMG_PLAN_OL_Class_58_Online
This class is devoted entirely to Interchange standards including authority, modifications, confirmations, implementation and exemptions.
Credit: 8CEH (8OP,8STDS,8PROF,1EO)
Sections
- 58.1 - Interchange Information
- 58.2 - Interchange Transaction Information
- 58.3 - Interchange Transaction Modifications
- 58.4 - Authority Distributes Arranged Interchange
- 58.5 - Response to Interchange Authority
- 58.6 - Interchange Confirmation
- 58.7 - Interchange Authority Distributes Status
- 58.8 - Implementation of Interchange
- 58.9 - Interchange Coordination Exemptions
$160.00 59 - Protection and Control Part 1
TEG_103_PROT_CONT_PT1_OL_CLASS_59
This class is Part 1 coverage of Protection and Control including disturbance, transmission and generation misoperations, maintenance and testing, and Under Frequency Load Shedding.
Credit: 8CEH (8OP,8STDS,8PROF,3EO)
Sections
- 59.1 - Protection and Control
- 59.2 - Define Regional Disturbance Monitoring and Reporting
- 59.3 - Regional Procedure for Analysis of Misoperations of Transmission and Generation Protection Systems
- 59.4 - Analysis and Mitigation of Transmission and Generation Protection System Misoperations
- 59.5 - Transmission and Generation Protection System Maintenance and Testing
- 59.6 - Development and Documentation of Regional Reliability Organizations\\\' Underfrequency Load Shedding Programs
- 59.7 - Assuring Consistency with Regional UFLS Program Requirements
- 59.8 - Underfrequency Load Shedding Equipment Maintenance Programs
$160.00 60 - Interconnection Reliability Operations and Coordination
TEG_103_INTC_REL_COORD_OL_Class_60_Online
This class deals directly with Reliability Coordinator authority, responsibilities, procedures and communications.
Credit: 8CEH (8OP,8STDS,8PROF,4EO)
Sections
- 60.1 - Reliability Coordination - Responsibilities and Authorities
- 60.2 - Reliability Coordinator - Facilities
- 60.3 - Reliability Coordination - Wide Area View
- 60.4 - Reliability Coordination - Operations Planning
- 60.5 - Reliability Coordination - Current Day Operations
- 60.6 - Reliability Coordination - Transmission Loading Relief
- 60.7 - Procedures, Processes, or Plans to Support Coordination Between Reliability Coordinators - Notifications and Information Exchange Between Reliability Coordinations
- 60.8 - Coordination of Real-Time Activities Between Reliability Coordinators
$140.00 61 - Protection and Control Part 2
TEG_103_PROT_CONT_PT2_OL_CLASS_61
This class is Part 2 (Part 1 is Class 59) of Protection and Control including UFLS maintenance and testing, SPS procedures, documentation, maintenance and testing.
Credit:7CEH (7STDS,7PROF,7OP,1.5EO)
Sections
- 61.1 - UFLS Equipment Maintenance Programs and UFLS Performance Following an Under Frequency Event (1/5)
- 61.2 - Assessment of the Design and Effectiveness of UFLS System Maintenance and Testing (2/5)
- 61.3 - Special Protection System Review Procedure and Special Protection System Database (3/5)
- 61.4 - Special Protection System Assessment and Special Protection System Data and Documentation (4/5)
- 61.5 - Special Protection System Misoperations and Special Protection System Maintenance and Testing (5/5)
The Energy Group